CASE 02 · E. COLI LACTOSE REGULATION
When does feedback
switch on, and when does growth push back?
Explore the loop linking lactose uptake, allolactose, LacI release, enzyme production, and growth-linked dilution.
Change the environment
Parameters are normalized for exploration, not fitted to measured data.
Arrange an experiment
Set the starting medium above, then schedule any number of lactose/glucose changes.
No scheduled changes. The starting condition stays constant for 18 h.
Starting condition: 0.55 mM lactose · no glucose.
A CONTROLLED COMPARISON
Same medium. Different history?
Compare a steady condition with a short lactose pulse. Both return to the same medium; only the route there changes.
Stay in the starting medium through the 6 h readout.
At 2 h, switch lactose briefly; at 5 h, return to the starting medium for the final hour.
| 6 h state | Steady | Pulse | Difference |
|---|
This compares two runs of the same reduced deterministic model. It illustrates modeled state-dependence, not measured biological memory or experimental evidence.
A MODEL IDENTIFIABILITY CHALLENGE
One measurement. Two parameter explanations.
Calibrate a second parameter set to the same 6 h enzyme proxy, then apply the same lactose pulse to both. Which state variable separates their predictions?
The comparison starts from the current sliders and keeps the same glucose context. Calibrated values are model parameters, not experimental estimates.
No comparison run yet.
| Readout | Reference | Alternative | Difference |
|---|
Choose the next measurement
Under the same 2–5 h pulse, rank candidate readouts and timepoints by predicted separation.
Run the calibration to rank follow-up measurements.
| Rank | Readout | Time | Reference | Alternative | Difference | Noise units |
|---|
Noise is a user-chosen equal absolute scale in normalized model units, not measured assay precision. Rankings are conditional on this reduced model and are not laboratory instructions.
These are two parameterisations of the same reduced deterministic model, not two experimentally established mechanisms. The fitted LacI value may fall outside the slider range. Matching one modeled readout does not validate either parameter set; trajectory differences are model predictions, not biological evidence.
Mechanism map
State variables update from the coupled rate equations.
Positive feedback: LacY helps import lactose; LacZ helps form the natural inducer that increases lac expression.
Growth dilutes Li · inducer · enzymesCompare predictions
Switch between the dose response and the current time course.
Each line is one normalized state variable. The curves are model output, not experimental observations.
The mechanism map is informed by Zander et al., Biophysical Journal (2017). This interactive reduction is not a reproduction of their fitted model or data.